Ep
oxy Resin Worktops
  Chemical Properties     

Test method A (for volatile chemicals):
A cotton ball, saturated with the test chemical (reagent), is placed in a 1-ounce test tube with a reservoir of liquid above the ball. The container is inverted on the test material at a standard temperature of 23℃ plus or minus 2℃ (73°plus or minus 4℉).

Test method B (for non-volatile chemicals):
5 drops (1/4cc) of the test chemical are placed on the test material surface. The chemical is covered with a watch glass (d=5cm) at a standard temperature of 23°plus or minus 2℃ (73°plus or minus 4℉).

For both the above methods (A and B), leave the reagents on the panel for a period of: 1 hour for exposed vertical surfaces and semi-exposed surfaces, 24 hours for exposed horizontal surfaces such as countertops. After exposure, exposed areas are washed with water, then a detergent solution, finally with naphtha, then rinsed with distilled water and dried with a cloth.


Reslut of Duchem Epoxy Resin Worktops

NO.

CHEMICALS

NO EFFECT

MINIMAL SPOT

SPOT

1.

Sulfuric Acid, 95%

-

X

-

2.

Hydrochloric Acid, 37%

-

X

-

3.

Nitric Acid, 40%

X

-

-

4.

Acetic Acid, 99%

X

-

-

5.

Sodium Hydroxide, 40%

X

-

-

6.

Hydrogen Peroxid, 10%

X

-

-

7.

Ethyl Alcohol, 99%

X

-

-

8.

Acetone, 20%

X

-

-

9.

Methylene Chloride, 99%

X

-

-

10.

Diethyl Ether, 99%

X

-

-

11.

Xylene, 99%

X

-

-

12.

Alconox (Lab. Detergent)

X

-

-

13.

Enhanced valeraldehyde disindector, 2%

X

-

-

14.

Sterile pack fluid

X

-

-

15.

Wright's blood stain

X

-

-

16.

Giemsa Bloodstain Giemsa

X

-

-

17.

Gresol red

X

-

-

 
Copyright | © 2005-2010 Duchem, All rights reserved.
Add: Xinling Road, Xiaolong Village, Shiji Town, Panyu District, Guangzhou, China
Tel: 86-20-3488 2350          Fax: 86-20-3996 1079
E-mail: duchem@duchem.com.cn , sales3@duchem.com.cn